How to solve hydraulic system overheating problems

Hydraulic Supermarket logo

I was asked recently to investigate and solve an overheating problem in a mobile hydraulics application. The hydraulic system comprised a diesel-hydraulic power unit, which was being used to power a pipe-cutting saw. The saw was designed for sub-sea use and was connected to the hydraulic power unit on the surface via a 710-foot umbilical. The operating requirements for the saw were 24 GPM at 3000 PSI.

Why do hydraulic systems overheat?

Heating of hydraulic oil in operation is caused by inefficiencies. Inefficiencies result in losses of input power, which are converted to heat. A hydraulic system's heat load is equal to the total power lost (PL) through inefficiencies and can be expressed as:

PLtotal = PLpump + PLvalves + PLplumbing + PLactuators

If the total input power lost to heat is greater than the heat dissipated, the hydraulic system will eventually overheat.

Hydraulic oil temperature - how hot is 'too hot'?

Hydraulic oil temperatures above 180°F (82°C) damage most seal compounds and accelerate degradation of the oil. While the operation of any hydraulic system at temperatures above 180°F should be avoided, oil temperature is too high when viscosity falls below the optimum value for the hydraulic system's components. This can occur well below 180°F, depending on the oil's viscosity grade.

Maintaining stable hydraulic oil temperature

To achieve stable oil temperature, a hydraulic system's capacity to dissipate heat must exceed its inherent heat load. For example, a system with continuous input power of 100 kW and an efficiency of 80% needs to be capable of dissipating a heat load of at least 20 kW. It's important to note that an increase in heat load or a reduction in a hydraulic system's capacity to dissipate heat will alter the balance between heat load and dissipation.

Returning to the above example, the hydraulic power unit had a continuous power rating of 37 kW and was fitted with an air-blast heat exchanger. The exchanger was capable of dissipating 10 kW of heat under ambient conditions or 27% of available input power (10/37 x 100 = 27). This is adequate from a design perspective. The performance of all cooling circuit components were operating within design limits.

Pressure drop means heat

At this point it was clear that the overheating problem was being caused by excessive heat load. Concerned about the length of the umbilical, I calculated its pressure drop. The theoretical pressure drop across 710 feet of 3/4" pressure hose at 24 GPM is 800 PSI. The pressure drop across the same length of 1" return hose is 200 psi. The formula for these calculations is available here. The theoretical heat load produced by the pressure drop across the umbilical of 1,000 psi (800 + 200 = 1000) was 10.35 kW. The formula for this calculation is available here.

This meant that the heat load of the umbilical was 0.35 kW more than the heat dissipation capacity of the hydraulic system's heat exchanger. This, when combined with the system's normal heat load (inefficiencies) was causing the hydraulic system to overheat.

Beat the heat

There are only two ways to solve overheating problems in hydraulic systems:

  • decrease heat load; or
  • increase heat dissipation.

Decreasing heat load is always the preferred option because it increases the efficiency of the hydraulic system. In the above example, the heat load of the umbilical alone was nearly 30% of available input power, a figure that would normally be considered unacceptable. Decreasing this heat load to an acceptable level would have involved reducing the pressure drop, by replacing the pressure and return lines in the umbilical with larger diameter hoses. The cost of doing this for what was a temporary installation meant that, in this case, the most economical solution was to install additional cooling capacity in the circuit

Continuing to operate a hydraulic system when the oil is over-temperature is similar to operating an internal combustion engine with high coolant temperature. Damage is guaranteed. Therefore, whenever a hydraulic system starts to overheat, shut it down, identify the cause and fix it.

Related articles:

How is your hydraulic heat exchanger connected?
One type of hydraulic system you don't want
How to tell if your hydraulic equipment is 'sick'

If you enjoyed this article, you'll love Brendan Casey's Inside Hydraulics newsletter. It gives you real-life, how-to-do-it, nuts-and-bolts, hydraulics know-how -- information you can use today. Here's what a few members have said about it:

Can't Put It Down
?I get e-mails like this all the time. I never find time to read them. I decided to read Issue #30 and I couldn't put it down. I'll make time from now on.?

Richard A. Shade, CFPS, Project Engineer (Hydraulic Design), JLG Industries Inc.

So Valuable It Earned Me A Raise
?The knowledge I've gained from this newsletter has been so valuable it has earned me a raise!?

Jack Bergstrom, Heavy Equipment Mechanic, Sharpe Equipment Inc.

Love It - Keep Them Coming
?I just love this newsletter. As a Hydraulics Instructor for Eaton, I make copies and distribute them to my students as I address various topics. Please keep 'em coming.?

Michael S Lawrence, Hydraulics Instructor, Eaton Hydraulics Inc.

To get your FREE subscription ($149 value), simply type your first name and primary email address into the form below and hit 'SUBSCRIBE NOW!'

YES, I want to improve my hydraulics knowledge!

This is a private mailing list that will NEVER be shared for any reason.
You can also unsubscribe at anytime.

Home Page



Copyright © 2000 - 2013 Brendan Casey; HydraulicSupermarket.com