How To Stop Hydraulic Filters ‘Clicking’

Filter used on a filter cartBased on my experience at least, electrostatic discharge in hydraulic systems is not a widespread problem. But for reasons I’ll explain in a moment, it may be on the increase. So it’s definitely something you need to be aware of.

As you probably remember from school science experiments, electrostatic charge is generated whenever there is friction between two bodies moving … Read more

Hydraulic Pump ‘Dry Starts’ and How To Avoid Them

pressurized hydraulic systems are dangerousOne of our members wrote me with this question:

“I was subcontracted to remove a 30 GPM, 4000 PSI rated hydraulic pump from one plastic injection press and install it into a similar hydraulic system for the same company.

The hydraulic pump and prime mover are both beside and below (approx 12″) the bottom of the reservoir; a “flooded inlet” … Read more