How To Store Hydraulic Cylinders — Safely

hydraulic cylinder failureA question I get asked a lot by equipment owners, is the procedure for storing spare hydraulic cylinders for an extended period. So here’s what I recommend:

–Always store fully retracted.
–Store indoors in a clean, dry area.
–Smear the internal surfaces of eye/clevis bushes or bearings with grease – particularly if they’re steel.
–Protect any exposed chrome on the … Read more

How To Make Sense Of Case Drain Flow From A Hydrostatic transmission

big question markOne of our readers recently wrote me regarding the following problem:

“I tried one afternoon and evening to determine what was wrong with a hydrostatic transmission by monitoring case drain flow and was confused by the readings I was seeing. There was a flow meter in the transmission pump outlet and another in its case drain that always showed charge … Read more