How To Size A Hydraulic Tank

how to heat hydraulic oil safelyWhen it comes to sizing a hydraulic reservoir, my motto and advice is the bigger the better. Because the greater the tank volume the longer the dwell time the oil has to give up contaminants – particles, water and particularly air. Size DOES matter.

The rules of thumb for reservoir size – and that’s all they are – differ for open and closed circuits. For open circuits the general rule is a tank oil capacity of 3 to 5 times the flow of the pump(s) per minute plus a 10 percent air cushion. For HFC and HFD fire-resistant fluids the general rule is 5 to 8 times pump flow per minute.

These ideals are easy enough to achieve on a stationary hydraulic machine in an industrial setting. In a mobile application it’s a lot harder due to space and weight restrictions. For this reason, 1.5 to 2 times pump flow-rate is often a more realistic target for mobile machines.

Realistic, but not necessarily ideal. So, for example, if I was designing a mobile hydraulic machine and it was possible to squeeze in a tank volume of say 2.5 times pump flow rate per minute – I’d definitely do it. Like I say, the bigger the better.

That takes care of open circuit systems. But what about closed circuits (hydrostatic transmissions)? If the transmission pump has a flow rate of 100 gallons per minute, should the target tank volume be 300 to 500 gallons? No, that would be overkill. The flow rate of 100 gallons per minute is not passing through the tank. It is circulating in the transmission loop – pump to motor and back to pump.

But the charge pump on a hydrostatic transmission is open circuit, right? So how about 3 to 5 times the flow-rate of the charge pump per minute? If the transmission pump has a maximum flow-rate of 100 gallons per minute, then the charge pump would need to have a flow rate of at least 20 percent of that or 20 gallons per minute. Based on the 3 to 5 times rule, that equates to a tank volume of between 60 and 100 gallons. Certainly no harm in having a tank that size – if it can be accommodated. Once again, in a mobile application, 1 to 2 times charge pump flow per minute is probably more realistic. And even that’s extremely generous compared to what some hydrostatic transmission manufacturers recommend. Here’s what Sauer-Danfoss recommends for their Sundstrand 90 Series transmissions:

“A suggested minimum total reservoir volume is 5/8 of the maximum charge pump flow per minute with a minimum fluid volume equal to 1/2 of the maximum charge pump flow per minute. This allows 30 seconds fluid dwell for removing entrained air at the maximum return flow. This is usually adequate to allow for a closed reservoir (no breather) in most applications.”

Well, 30 seconds of dwell time isn’t much. And unless I’ve been living in a cave all these years, closed or pressurized reservoirs are the exception rather than the norm. So while having a definitive recommendation like this from the manufacturer is reassuring, I’d say 1/2 to 5/8 of charge pump flow per minute is being ridiculously stingy in the majority of closed-circuit applications. And to discover six other costly mistakes you want to be sure to avoid with your hydraulic equipment, get “Six Costly Mistakes Most Hydraulics Users Make… And How You Can Avoid Them!” available for FREE download here.

6 thoughts on “How To Size A Hydraulic Tank

  1. Hi Brendan,
    Generally I agree with you, that a bigger tank is better for a hydraulic system. But there is one big exception to that rule: My company is making compact power units with leakage free seated valves, designed for running in on/off mode. For these units you can really size the reservoir as small as possible, because the unit is only activated when hydraulic energy is required in the system. That allows to sizing the reservoir not according to the flow of the unit but according to the requirement of the actuators.
    That does not only save space but you can also save a huge amount of money with each oil change.
    Kind regards
    Axel

    • Axel,

      Yes, good point. In fact, there ARE innovations with respect to tank design which permit the tank to be smaller than the rules of thumb mentioned above, without compromising air release–which is one of the main reasons for the bigger is better mantra.

      Thanks for your view point.

      Regards,

      Brendan

    • Hi Alex
      Interesting thoughts!
      I’m working on designing a small servo hydraulic system and I’d be interested in hearing more about your products.

  2. I just bought a hyd log splitter before finding this site. The pump is a 2 stage hi/lo pump 53.28L/min (preset 650psi adjustable to 913psi) low pressure/ 6.48L/min high pressure,3000 psi . The tank is is only 10.5-11L plus air space.
    Should the tank sizing be ideally based on the total flow or the high pressure flow?